CSA制冷空调认证报告英文版doc47页正式版
MASTERCONTRACT:
218317
REPORT:
1965853
PROJECT:
1965853
Edition1:
June28,2007;Project1965853–Toronto
Preparedby
Contents:
CertificateofCompliance-Page1
SupplementtoCertificateofCompliance-Page1
DescriptiveReportandTestResults-Pages1to80
Illustrations-Ills1to9
Figures-Figs1to14
Attachment-Atts.AandB
PRODUCTS
CLASS121105-COMFORTCONDITIONINGEQUIPMENT(ELECTRICAL)–AirConditioners
CLASS121185-COMFORTCONDITIONINGEQUIPMENT(ELECTRICAL)-CERTIFIEDTOU.S.STANDARDS
CentralAirConditioners,ductedunit,permanentlyconnected,consistingofanaircooledoutdoorunitandamatchingindoorunit,usingrefrigerantR410A,withmodelnumbersandratingsshownasfollows:
PARTA:
Outdoorunit,BORAModel24CHSRA,rated208/230V,60Hz,1phase.
PARTB:
Outdoorunit,BORAModel30CHSRA,rated208/230V,60Hz,1phase.
PARTC:
Indoorunit,CARRIERModelFE4ANF005,rated208/230V,60Hz,1phase.
APPLICABLEREQUIREMENTS
CAN/CSA-C22.2No.236-05-HeatingandCoolingEquipment.
ULStandadNo.1995-HeatingandCoolingEquipment.
MARKINGS
INDOORUNIT:
Notapplicable.TheindoorunitisanULlistedfancoilunitandismarkedinaccordancewithULcertificationreport.
OUTDOORUNIT:
ACSAAcceptedorULRecognizedadhesivetypenameplateCertifiedforoutdooruse,isaffixedtotheoutsideofthecabinetbearsthesubmittor'snameorfilenumber"218317",modeldesignation,dateofmanufacture,completeelectricalratinginvolts,hertz,numberofphases,inputampereratingofeachfanmotors,RLAandLRAofthecompressor,minimumcircuitampacity,"Max.OvercurrentProtection(FuseorHACRTypeCircuitBreaker):
A”,quantityandtypeofrefrigerant,thedesignhighandlowsidepressures,andtheCSAMonogramwiththe“CUS”indicator.
CautionWording:
WARNING:
RISKOFELECTRICSHOCK.CANCAUSEINJURYORDEATH:
DISCONNECTALLREMOTEELECTRICPOWERSUPPLIESBEFORESERVICING.
AVERTISSEMENT.RISQUEDECHOCSELECTRIQUES.
PEUTCAUSERDESBLESSURESETMEMEENTRAINERLAMORT.
COUPERLESSOURCESD’ALIMENTATIONADISTANCEAVANTLEDEPANNAGE.
Theabovecautionwordingmayappearonaseparateadhesivetypenameplateaffixedneartothemainnameplate.Labelsnotaffixedtoremovablecoverunlessotherwisespecified.
USECOPPERSUPPLYWIRES.
UTILISERDESFILSD’ALIMENTATIONENCUIVRE
Theabovecautionwordingappearsonaseparateadhesivetypelabelnearthemainterminalblock.
Thestatement“forusewithindoorunit,CARRIERMODELFE4ANF005”.
Suitablewiringdiagramisprovidedoneachunit(paperwiringdiagramisaffixedtotheaccesspanelinsidesurface).
Suitablewiringdiagramisprovidedontheunit.
Installationoperatingmanualisprovidedwitheachoutdoorunit.
Notes:
1."JurisdictionsinCanadamayrequirethesemarkingstobealsoinFrench.Itistheresponsibilityofthecustomertoprovidebilingualmarking,whereapplicable,inaccordancewiththerequirementsoftheProvincialRegulatoryAuthorities".
2.TheproductmaybeartheCSAlogo,orCSAwithUSindicator,orCSAwithCUSindicator.
ALTERATIONS
1.Themarkingsareasnotedabove.
FACTORYTESTS
1.DielectricWithstandTest:
Theequipment,uponcompletionofmanufactureandbeforeshipment,shallwithstand,fornotlessthanonesecond,withoutbreakdown,theapplicationofthefollowingacvoltages,betweenlivepartsandexposedmetalparts:
(a)1,000Vforunitswithamotorratedatlessthan1/2hpandrated250Vorless.
(b)1,000Vplustwiceratedvoltageforallotherunits.
Forunitswhichincludeextra-low-potentialcircuits(30Vorless),thetestistobeconductedwiththeextra-low-potentialcircuitconnectedtothecabinet,chassis,orotherdeadmetalpart,sothatthepotentialwhichisappliedbetweentheprimarycircuitandtheexposedmetalparts,isappliedsimultaneouslybetweentheprimarycircuitandtheextra-low-potentialcircuit.
(c)Forunitswhichincludeextra-low-potentialcircuits;500Vbetweentheextra-low-potentialcircuitandexposedmetalparts.
Note:
ThetestspecifiedinItem(c)maybewaived,iftheextra-low-potentialcircuitisgroundedorClass2.
2.PressureTestforRefrigerantLeakage:
Atthecompletionofmanufactureandbeforeshipment,thecompleterefrigerationsystemoftheequipmentshallbetestedandprovedtightatpressuresnotlessthanthehighestofthefollowing:
(a)Thedesignpressuresmarkedonthedataplateforthedevice.
(b)Theminimumtestpressurestabulatedbelow.
Refrigerant
MinimumDesignPressure*
LowSide
HighSide
kPa
psig
kPa
psig
22
993
144
1917
278
500
703
102
1400
203
502
1117
162
2082
302
134a
593
86
1282
186
R407C
1142
166
2191
318
R410A
1622
235
3075
446
Notes:
*Amethodotherthanpressuretestingatthedesignpressuremaybeemployedifitcanbedemonstratedthatthealternativetestmethodproducesresultsthatareatleastequivalenttothepressuretestmethod.
Theleakagetestonthecompletesystemmaybeconductedattheindicatedlowsidepressureiffinalassemblyoftheequipmentiscompletedwithflare-typefittingsortelescopedtubingjointsthataresealedwithsilversolder,brazing,orequivalentmeansprovidedthehighsidepartsareCSACertifiedrefrigerantcontainingcomponentparts,orindividuallytestedatnotlessthanhighsidepressureindicated.
Warning:
Thefactorytest(s)specifiedmaypresentahazardofinjurytopersonneland/orpropertyandshouldonlybeperformedbypersonsknowledgeableofsuchhazardsandunderconditionsdesignedtominimizethepossibilityofinjury.
DESCRIPTION
Thedescriptionofeachsectionisgroupedasfollow:
Section
Number.Description
10Markings
20Cabinetandmetalenclosures
30Nonmetallicenclosureandparts
40Refrigerationsystemcomponents
50Compressors
60Fanmotors
70Electricalcomponents
80Internalwiring
AttachmentDescription
A.InstallationmanualofBoraoutdoorunits.
B.InstallationmanualofCarrierfancoilindoorunits.
PRODUCTDECRIPTION:
TheproductscoveredinreportarecentralairconditioningsystemseachconsistingofanoutdoorunitmadebyBORAmatchedwithanULlistedindoorfancoilunitmadebyCarrieraslistedbelow:
OutdoorUnitModel
MatchingIndoorUnitModel
24CHSRA
CARRIERModelFE4ANF005
30CHSRA
Thesemodelseachconsistsofafactorychargedoutdoorunit,whichisjoinedinthefieldbyelectricalconduitandrefrigerationtubing,totheindoorfancoilunit.Therefrigerantforthetotalsystemisdeterminedintheendinstallation.
Theoutdoorunitandtheindoorunitarepermanentlyconnectedtoitsownseparatepowersupply.
Electricalinterconnectionbetweentheindoorandoutdoorunitsconsistsofextralowvoltagecontrolcircuitwiringonly.
GENERALREQUIREMENTS:
ComponentsareCSACertifiedorULListedorRecognized,oracceptedintheendproduct.
ELECTRICALSPACINGS:
UnlessotherwisenotedinthisReport,thespacingsbetweenuninsulatedlivepartsofoppositepolarityandbetweenuninsulatedlivepartsanddead-metalpartsarenotlessthanthefollowing:
RatingsMinimumspacingin.(mm)
Volts-AmperesVoltsThroughAirOverSurfaceToEnclosure
2000orless0to3001/8(3.2)1/4(6.4)1/4(6.4)
301to7503/8(9.6)½(12.8)½(12.8)
Morethan20000to3001/4(6.4)3/8(9.5)1/2(12.7)
INSTALLATIONINSTRUCTIONS:
Eachunitisprovidedwithinstallationandoperatinginstructions.Theinstallationinstructionsshallspecifythemaximumlengthofinterconnectingtubingforfieldconnectionofcondensingsectionandevaporatingsection.
CORROSIONPROTECTION:
Allferrousmetalpartsusedtosupportorretainelectricalcomponentsinpositionareprotectedagainstcorrosionbyazinccoatingandpainting.
WIRING:
Unlessotherwisenotedinthisreport,allwiringisCSACertifiedorULRecognizedR/CAVLV2,min18AWG,suitableforaminof300V.Itisinstalledandpositivelyroutedinsuchamannerthatitisnotsubjecttomechanicaldamageduetocontactwithsharpedges,abrasivesurfaces,vibratingormovingparts.Wiringwhichiscompletelyenclosedwithinmetalconduit,metalracewaysorotherseparateelectricalenclosureemploys2/64in(0.8mm)thickminelectricalinsulationunlessspecifieddifferentlyinthisReport.
Greenorgreenwithayellowstripemaybeemployedonlyasgroundingconductors.
Allroutingofwiringthroughmetalpanelsismadethroughholesprovidedwithbushingswithresilientrubberorholesforthepassageofwiresorcordsthroughwall,panelsorbarriershavingsmooth,roundedsurfaces.
MARKINGS:
Allmarkingsrequiredtobepermanentshallbemolded,diestamped,paintstenciled,stampedoretchedonpermanentlysecuredmetal,orindeliblystampedorpaintedonpressuresensitivelabelssecuredbyadhesive.PressuresensitivelabelsshallbeCSAAcceptedorULrecognizedU/CPGDQ3,orR/CPGDQ2.Fortheoutdoorunits,thePressuresensitivelabelsshallbeapprovedforoutdooruse.
GENERALCONSTRUCTIONDESCRIPTION
PARTA:
Outdoorunit,BORAModel24CHSRA.
InstallationinstructionsoftheoutdoorunitwiththeCarrierindoorunittoformamatchedcentralACsystem,isasshowninAttachmentA.
ThematchedACsystemhasattainedaSEERratingof13(seeEEVreport218317-1965855).
ThematchedACsystemhasattainedaCanadianHSPFratingof6.7(seeEEVreport218317-1965855).
ThematchedACsystemhasattainedaUSAHSPFratingof7.7(seeEEVreport218317-1965855).
10MARKING:
SeeIlls1fordetails.
10-10NameplateMarking