CiscoMCMTS常用指令集Word下载.docx
- 文档编号:8683091
- 上传时间:2023-05-12
- 格式:DOCX
- 页数:26
- 大小:91.26KB
CiscoMCMTS常用指令集Word下载.docx
《CiscoMCMTS常用指令集Word下载.docx》由会员分享,可在线阅读,更多相关《CiscoMCMTS常用指令集Word下载.docx(26页珍藏版)》请在冰点文库上搜索。
17.Showcableclock
18.Showcableclockdticounters
ToverifythattheWidebandSIPispoweredon,usetheshowdiagcommand.Ifshowdiagdisplaysanyoutput,theWidebandSIPispoweredon.TheshowdiagcommandprovidesavarietyofinformationontheWidebandSIP.Inthefollowingexample,thehardwaretypeoftheWidebandSIPis2jacket-1card.
Router#showdiag1/0
Slot/Subslot1/0:
2jacket-1card,0ports
Cardisfullslotsize
Cardisanalyzed
Carddetected16:
46:
44ago
Carduptime0days,16hours,46minutes,36seconds
Cardidletime0days,14hours,22minutes,34seconds
Voltagestatus:
3.3VNominal2.5VNominal1.5VNominal12VNominal
EEPROMcontents,slot1/0:
HardwareRevision:
1.0
TopAssy.PartNumber:
800-22843-04
BoardRevision:
01
DeviationNumber:
0-0
FabVersion:
04
PCBSerialNumber:
CSJ09030613
RMATestHistory:
00
RMANumber:
0-0-0-0
RMAHistory:
CLEICode:
...
Ifshowdiagdisplaysnooutput,theWidebandSIPisnotpoweredon.
Router#showdiag1/0//Displaysnooutput
showdiag1/0/0
TodisplayhardwareanddiagnosticinformationforaWidebandSPA,usetheshowdiagcommand.
Router#showdiag1/0/0
Slot/Subslot/Port1/0/0:
24rfchannel-spa-1card,1port+1redundantport
Cardishalfslotsize
47:
55ago
Carduptime:
NotSupported
Cardidletime:
3.3V(+3.291)NOMINAL2.5V(+2.495)NOMINAL
1.2V(+1.201)NOMINAL1.8V(+1.811)FIXED
EEPROMcontents,slot1/0/0:
BootTimeout:
500
CSJ09379726
PartNumber:
73-9597-03
PartNumberRevision:
05
03
0
Product(FRU)Number:
SPA-24XDS-SFP
VersionIdentifier(VID):
V01
68-2562-03
MACAddress:
0019.06a5.d9b2
MACAddressblocksize:
1
ManufacturingTestData:
0000000000000000
FieldDiagnosticsData:
CalibrationData:
Minimum:
0dBmV,Maximum:
0dBmV
Calibrationvalues:
Platformfeatures:
0000000000000000
00000000000000
2.Showhw-modulebayoir
ToverifythattheWidebandSPAispoweredon,usetheshowhw-modulebayoircommand.Ifthe
OperationalStatusis“ok,”theWidebandSPAispoweredonandoperational.
Router#showhw-modulebay1/0/0oir
ModuleModelOperationalStatus
---------------------------------------------------------
bay1/0/0SPA-24XDS-SFPok
Ifshowhw-modulebayoirdisplays“admindown”intheOperationalStatusfield,theWidebandSPA
hasbeenadministrativelydisabled.
bay1/0/0SPA-24XDS-SFPadmindown
3.Showcontrollersmodular-cable
WithCiscoIOScommands,theWidebandSPAanditsGigabitEthernetportsarenotconsideredstandarduser-configurableinterfacesanddonotappearintheoutputoftheshowinterfacescommand.TheWidebandSPAisacontrollerandtheshowcontrollersmodular-cablecommanddisplaysinformationabouttheSPA,itsGigabitEthernetports,installedSFPmodules,widebandchannels,andsoon.
Thefollowingexampleprovidessampleshowcontrollersmodular-cableoutputfortheWidebandSPAlocatedinslot1,subslot0,bay0ofaCiscouBR10012router.Intheoutput,theGigabitEthernetPortSelectedfieldindicatesthatPort1istheactiveGigabitEthernetportontheWidebandSPA.
Router#showcontrollersmodular-cable1/0/0brief
SPA0ispresent
statusLED:
[green]
Host12Visenabledandisokay.
PowerhasbeenenabledtotheSPA.
SPAreportspowerenabledandokay.
SPAreportsitisokayandisNOTheldinreset.
GigabitEthernetPortSelected:
Port1
ReceiveInterface:
InReset
Disabled
TransmitInterface:
OutofReset
Enabled
PrimaryReceiveClock:
BackupReceiveClock:
SFP[Port0]:
1000BASE-SXPresent
TxEnabled,LOSDetected,TxFaultNotDetected
LinkStatus[Port0]:
DOWN
SFP[Port1]:
1000BASE-TPresent
TxEnabled,LOSNotDetected,TxFaultNotDetected
LinkStatus[Port1]:
UP
Intheprecedingoutput,noticethefollowing:
•TheGigabitEthernetPortSelectedfieldindicatestheactiveGigabitEthernetport.
•FortheactiveGigabitEthernetport,theSFP[Port1]fieldindicatesthetypeofSFPmodulethatis
present.
•FortheactiveGigabitEthernetport,theLinkStatus[Port1]fieldindicateswhetherthelinkisup.
TheCiscoWidebandSPAtransmitsdatainaunidirectionalmanneronlyanddoesnotreceivedatafromdevicesconnectedtoitsactiveGigabitEthernetport.
IfthelinkfortheactiveGigabitEthernetportisnotup,checkthefollowing:
•TheSFPmoduleiscorrectlyinstalledandmatchestheSFPmoduleintheconnecteddevice.
•ThecablestotheWidebandSPAportsarecorrectlyconnectedtoapowered-ondevice.
•ThecablestotheWidebandSPAportsarenotbentordamaged.
•Ahardwarefailurehasnotoccurred.Forinformation,seethe“PerformingBasicTroubleshooting
onaWidebandSIPandWidebandSPA”sectiononpage5-19.
Usetheshowcontrollermodular-cablecommandwiththesfpkeywordtogetmoredetailed
informationontheSFPmodulesinstalledinaWidebandSPAGigabitEthernetports.
WidebandChannelinformation
ChannelRFbitmapPoliceInfo:
BytesInterval
00x300ms
10xC00ms
20x3000ms
30xC000ms
40x30000ms
50xC0000ms
60x300000ms
70xC00000ms
80x3000000ms
90x000ms
100x000ms
110x000ms
RFChannelinformation
Modulationcorrespondsto:
QAM256
Annexcorrespondsto:
AnnexB
ModulationData:
GEInterframeGap=12,MPEG-TSFramesperpkt=4
SPAIPaddress=0.0.0.0SPAMACAddr=0012.001A.888B
QAMChannelRateRateadjustState
001Enabled
101Enabled
201Enabled
301Enabled
401Enabled
501Enabled
601Enabled
701Enabled
801Enabled
901Enabled
1001Enabled
1101Enabled
1201Enabled
1301Enabled
1401Enabled
1501Enabled
1601Enabled
1701Enabled
1801Enabled
1901Enabled
2001Enabled
2101Enabled
2201Enabled
2301Enabled
InterruptCounts
IdxInterruptRegisterInterruptBitTotalCountMasked:
69blz_sp_int_stat_reg_0spi_train_vld24YES
84spa_brd_int_stat_regsp_int_024NO
85spa_brd_int_stat_regscc_int2NO
86spa_brd_int_stat_regphy1_int1NO
87spa_brd_int_stat_regphy0_int1NO
92spa_brd_int_stat_regtemp1_int2NO
93spa_brd_int_stat_regtemp0_int2NO
97bm_int_stat_regbm_spa_brd26NO
TodisplayinformationabouttheSFPmoduleinaWidebandSPAport,usetheshowcontrollers
modular-cablewiththesfpkeyword.Inthefollowingexample,theinformationisfortheSFPmodule
inport1.
Router#showcontrollersmodular-cable1/0/0sfpport1
SFPinport1
SFPispresent
SFPLOSisnotdetected
SFPTXFAULTisnotdetected
SFPTXisenabled
ID:
SFP
ExtendedID:
4
Connector:
LC
SONETcompliance:
notspecified
GigabitEthernetcompliance:
1000BASE-SX
FibreChannellinklength:
FibreChanneltransmittertechnology:
FibreChanneltransmissionmedia:
FibreChannelspeed:
Encoding:
8B10B
BitRate:
1300Mbps
50micron-multimodefibersupportedlength:
550m
62.5micron-multimodefibersupportedlength:
270m
Upperbitratelimit:
Lowerbitratelimit:
Datecode(yy/mm/dd):
05/02/23
Vendorname:
CISCO-AGILENT
VendorOUI:
12499
VendorPartNumber(PN):
QFBR-5766LPVendorRev:
VendorSN(SN):
AGS090855CE
Optionsimplemented:
LOSSignal
TXFaultSignal
TXDisableSignal
Enhancedoptionsimplemented:
none
Diagnosticmonitoringimplemented:
Idpromcontents(hex):
0x00:
0304070000000100000000010D000000
0x10:
371B0000434953434F2D4147494C454E
0x20:
54202020000030D3514642522D353736
0x30:
364C50202020202020202020035200B5
0x40:
001A0000414753303930383535434520
0x50:
202020203035303232332020000000C4
0x60:
000006C9F0FA7C01B3C8416B3904FC85
0x70:
BB209E000000000000000000B49452CC
0x80:
FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
0x90:
State:
Initalized
PhasedInitialization
PhaseReached:
PhaseExitCode:
PhaseReadOffset:
4.Showcontro
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CiscoMCMTS 常用 指令