智能医院控制系统中英文对照外文翻译文献文档格式.docx
- 文档编号:6521654
- 上传时间:2023-05-06
- 格式:DOCX
- 页数:14
- 大小:23.49KB
智能医院控制系统中英文对照外文翻译文献文档格式.docx
《智能医院控制系统中英文对照外文翻译文献文档格式.docx》由会员分享,可在线阅读,更多相关《智能医院控制系统中英文对照外文翻译文献文档格式.docx(14页珍藏版)》请在冰点文库上搜索。
1.UniformlyManages,controlsandprotectsthehospitalillumination,airconditionersandthemedicalequipment
2.Enhancesthehospitalservicescale,providesthecomfortableenvironmenttothemedicalpersonandthepatients.
3.Savetheenergy,savesthehospitaloperationcosts
4.usesthesafevoltagetheweakelectricityboardtosubstitutethestrongelectricityboard,enhancedthesecurity;
Throughtheelectriccurrentandtheleakageelectriccurrentexaminationtotheimportantmedicalequipment,promptlyreportedinthebreakdownsituation,strengthenedthemedicalequipmentreliabilityandsecurity.
Functions:
1.Lightcontrolofwardandoutpatientservicebuilding
2.Electricalwindowcurtainandvisorvolumecurtaincontrolofwardandoutpatientservicebuilding
3.Airconditioner,heatsupandtheairblowerplatetubecontrolofwardandoutpatientservicebuilding
4.Illuminationandthelightadjustingoftheoperatingroomandthetreatmentroom
5.Hospitalwardringingsystem
6.AVdevicecontrolofacademicexchangecenterandconferenceroom
7.Illuminationelectricalpowerdistributionsystemandfirelinkage
8.Linkagehospitalautomationofficesystem,torealizetohavenopaperwork
9.All
T-bussystemintelligentcontrollers
circuitbreakerofOutpatientserviceandin-patientdepartmentandimportantmedicalequipmentcircuitbreakerconditionsurveillance
10.Centralismmonitorandcontroloftheoutpatientserviceandthehospitalwardtoachievethenon-boardcontrolinthepublicregion
Controlledareaandcontrolcontent:
1.hospitalward
Controloflight,electriccurtain,fancoilunit,ringingsystem,thesocketofmicrowaveovenandsoon,ultravioletraysterilizationlamp
2.Outpatientservicehall
Controloflight,visorvolumecurtain,fancoilunit
3.Thedepartmentsofthetreatment,theinspection,thesurgery,thediagnosis,rescueandsoon.
Controloflight,electriccurtain,fancoilunit
4.Commonaisle,elevatorhall
Controloflight,undergroundlampcontrol
5.Academicexchangecenter,reporthall
Controloflight,AVequipment,windowelectriccurtain,theatercurtain;
6.Extensivelighting,botanicalgardenillumination
Controloflight
7.Centercontrolcomputer
Solutions:
1.Hospitalward
*Installs8path2.4GHz
T-bussystemintelligentcontrollersbesidethebed,controlsthelightswitchandadjuststhelightintheguestroom,controlstheopeningandclosingoftheelectriccurtain,maycarryonthemasterswitchcontroltothehospitalwardlight,maycontrolthebathroomlight,andmaysetthedoctorsclinicscene,therestscene,thetelevisionwatchingscene.
*TheangleofthehospitalwardelectricallyoperatedbedcanbeadjustedthroughtheT-bussystemintelligentcontrollersandtheremotecontrol,facilitatesthedoctorsclinicandthepatientdines,reads;
*Guardianshipringingsystem.Whenthepatientneedstheguardianshipthepatient’sfeelingisnotgood,maypressthecallbuttonortheremotecontrolnearbythebed,theon-dutynursemayrushtothehospitalwardtocarryonprocessingimmediately;
*ThecentercontrolcomputerinEachfloornursestandcanimplementthecommoncontroltovariousillumination,thecurtainandtheair-conditionersystemathospitalwardsincorrespondingfloor,andthecomputerofeachnursestandcandemonstratetheindoortemperatureineachhospitalward,simultaneouslymayestablishthemaximumandminimumtemperature,providesthehumannatureservice;
*Thehospitalwardcorridorilluminationmayautomaticallyopenbycoordinatingwiththelightsensorandthetimers,whenthedegreeofilluminationrequestisverylowatthedeepernight,
shutsdownpartialilluminationslight,thefootlightautomaticallyopens.
*Thenursestationmayrealizecentralismmonitoringtothesocketsofvariousmedicalequipmentssuchasbreathmachineandsoonintheward.
*Installsaintelligentswitchwithatemperaturecontrolboardattheentrance,carriesontheautomaticconstanttemperaturecontroltothefancoilunitofthehospitalward,maydemonstratetheindoortemperature,simultaneouslymaycarryonthecontroltothelightandthecurtain.
*Installsintelligenceswitchatthebathroomentrance,maycarryonthecontroltothebathroomlightandtheventilatingfan
*Ifwithintelligentdoorlocksystemlinkage,mayrealizethedifferentopeninggatepatternbetweenthedoctorandtheserviceperson,namedtheclinicpatternandthesweepsclearpattern.
*AfterthepatientCheck-in,automaticallyadjuststhelightandtheelectriccurtainatthecorrespondingwardtoin-patientpattern,adjuststheairconditionertemperaturetocomfortabletemperature.Enablesthepatienttohavethehomefeelingandenhancesthehospitalservicescale.
*Afterthepatientleft,automaticallyadjuststhelightandtheelectriccurtainatthecorrespondingwardtoclosurepattern,mayautomaticallyrestorethewardhypothesistemperaturetotheconditionwhichtacitlyapproves.
*Afterthepatientgoestosleepatnight,T-bustemperaturecontrolsboardautomaticallychangestoenergyconservationpattern.Accordingtothestatistics,thehypothesistemperatureelevates1(whenrefrigeration)orreduces1(whenheatsup)everytime,mayconserveenergy6%
*Thecentercontrolroommaydemonstratetheactualtemperatureandthehypothesistemperatureofeachhospitalward.Alsomaysetthemaximumandminimumtemperature.Simultaneouslythehospitalwardtemperaturecontrolalsomayconnectwiththewindowlinkage,afterthewindowisturnedon,automaticallyclosestheairconditionertorealizeenergyconservationfully.
*T-bustemperaturecontrolsboardcanautomaticallycontrolFancoilunit.Whentheindoortemperatureapproachesthehypothesistemperature,automaticallyadjustswindspeedfromhightolow,makestheindoortemperaturetomaintainaroundthehypothesistemperature,tosaveenergyanditisverycomfortable.
*Whensummersunlightisintense,automaticallyshut-offwardcurtain,preventedthewardtemperaturetobeexcessivelyhigh,achievestheenergyconservationpurpose.
2.Outpatientservicehall
*Automaticallycontroldegreeofilluminationoftheoutpatienthallthroughlitsensoratdaytime.Whenthenaturallightisintense,closespartiallights,otherwise,thenopensthecertainlight,makestheoutpatienthalltomaintaintheconstantdegreeofillumination.Simultaneouslymayconserveenergy.
*Atnightmayactdifferentdegreeofilluminationaccordingtothepatientcurrentcapacity.
*Controlsthevisorvolumecurtainofthehallthroughthelightsensor.Whenthesummerlightisintense,automaticallylaysdownthevisorvolumecurtain,inordertoconservesenergy.
*Maycontrolthelight,thevisorvolumecurtainoftheoutpatienthallthroughthecentercontrolroomcomputer.
3.Thetreatmentoftheinspection,thesurgery,thediagnosis,therescueandsoon
*Theoperatingroom,therequirementofgeneraldegreeofilluminationisnotlowerthan1000Lux.Theshadowlesslamptookasthelocallighting,shouldachieveabove20000Luxinthesurgerytable30cmscope.MayadjustthelighttotheauxiliarylightsourcethroughtheT-bussystemintelligentcontrollersboardortheremotecontrol,mayadjuststhelightscopefrom0%to100%.
Accordingtodifferentoperatingroomilluminationdegree,speciallythelocallightingdegreeofilluminationisdifferent,Mayadjustthelightsourcedegreeofilluminationtocarryonthepre-establishment.
Throughilluminationdegreesensorestablishedintheoperatingroom,carryonthepreciseadjustmentofilluminationdegreetosomeworksurface.
*Regardsthefunctionalcheckingroom(mainlyrefertoophthalmologydepartment),itsrequirementofilluminationdegreereachesashighas7500Lux.ThroughtheT-bussystemintelligentcontrollerboardandtheremotecontrol,mayadjustthelightscopeaccordingtothehospitalilluminationstandardrequesttothe50Luxscope;
Inregardsthemirrorinspectionroom,Xperspectiveroom,theophthalmologydepartmentdarkroomandsoonthedegreeofilluminationisinthe50-100Luxscope,mayadjustthelightto0Lux.throughtheT-bussystemintelligentcontrollerboardandtheremotecontrol.
*stallstheelectriccurrentandtheleakageelectriccurrentexaminationmoduleregardingthebelowimportantadvancedequipment,likespiralCT,coloredDopplerBultramachine,theentireautomaticbloodcongealsanalyzer,theentireautomaticchemistrylightingimmunityanalyzer,24hoursdynamicelectroencephalogrammeter,straightverticalD5-3machine,thecentralguardianshipsystemandthebreathmachineandsoon.
Throughtheelectriccurrentandtheleakageelectriccurrente
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 智能 医院 控制系统 中英文 对照 外文 翻译 文献