一体化监控系统标准化作业指导书Word格式文档下载.docx
- 文档编号:3848968
- 上传时间:2023-05-02
- 格式:DOCX
- 页数:82
- 大小:86.76KB
一体化监控系统标准化作业指导书Word格式文档下载.docx
《一体化监控系统标准化作业指导书Word格式文档下载.docx》由会员分享,可在线阅读,更多相关《一体化监控系统标准化作业指导书Word格式文档下载.docx(82页珍藏版)》请在冰点文库上搜索。
4.2作业人员要求...................................................................................................................4
4.3试验仪器及材料...............................................................................................................4
4.4危险点分析及安全措施....................................................................................................4
服务器配置、电源及外观检查...............................................................................................5
5.1服务器外观、配置检查...........................................................................................5
5.2电源检查..................................................................................................................6
5.3线缆检查..................................................................................................................6
监控主机调试..........................................................................................................................7
6.1监控系统基本功能调试...........................................................................................7
6.1.1.主要人机画面检查...........................................................................................7
6.1.2.人员权限维护功能...........................................................................................8
6.2采集与控制功能调试...............................................................................................8
6.2.1.遥信功能调试...................................................................................................8
6.2.2.遥测功能调试...................................................................................................9
6.2.3.遥控、遥调功能测试.....................................................................................10
6.3全站通讯状态调试.................................................................................................12
6.4报表功能调试........................................................................................................13
6.5历史库功能调试....................................................................................................13
6.6智能告警与信息综合分析调试.............................................................................14
6.6.1.智能告警........................................................................................................14
6.6.2.信息综合分析.................................................................................................15
6.7顺序控制调试........................................................................................................15
6.8保护信息功能调试.................................................................................................16
6.8.1.保护定值召唤与修改.....................................................................................16
6.8.2.开关量及软压板调试.....................................................................................16
6.8.3.保护动作调试.................................................................................................17
6.8.4.故障录波装置接入检查.................................................................................17
6.8.5.故障录波功能检查.........................................................................................17
6.8.6.响应召唤功能调试.........................................................................................18
6.9一体化五防调试....................................................................................................18
6.9.1.监控五防........................................................................................................18
6.9.2.间隔五防........................................................................................................19
6.10无功控制调试........................................................................................................19
6.10.1.VQC功能调试................................................................................................19
6.11
6.12
6.13
与PMU集中控制器通讯调试...............................................................................20
对时调试................................................................................................................21
源端维护调试........................................................................................................21
6.14系统冗余可靠性调试.............................................................................................21
6.综合应用服务器调试............................................................................................................22
7.1系统接入................................................................................................................22
7.2综合应用服务器人机界面、数据采集调试.........................................................22
7.3联动控制调试........................................................................................................23
7.4设备状态可视化调试.............................................................................................23
7.数据通信网关机调试............................................................................................................24
8.1I区通信网关机远动功能调试...............................................................................24
8.2II区通信网关机功能调试......................................................................................24
8.3III/IV区通信网关机功能调试................................................................................25
8.4图形网关功能调试.................................................................................................25
8.4.1.远程浏览........................................................................................................25
8.4.2.告警直传........................................................................................................25
8.竣工........................................................................................................................................26
附录:
调试报告............................................................................................................................27
智能变电站一体化监控系统调试作业指导书
1.应用范围
本指导书适用于国家电网公司智能变电站110kV及以上电压等级一体化监控系统现场调试工作,规定了现场调试的准备、调试流程、调试方法和标准及调试报告等要求。
侧重对点、遥控,角度改变
2.引用文件
下列标准及技术资料所包含的条文,通过在本作业指导书中的引用,而构成为本作业指导书的条文。
本作业指导书出版时,所有版本均为有效。
所有标准及技术资料都会被修订,使用作业指导书的各方应探讨使用下列标准及技术资料最新版本的可能性
GB/T13729-2002
GB/T13730-2002
GB/T15153-2000
DL/T860-2004
远动终端设备
地区数据采集与监控系统通用技术条件运动设备及系统
变电站通信网络和系统
DL663-1999220kV~500kV电力系统故障动态记录装置检测要求
DL/T860
DL/T5149-2001220kV~500kV变电所计算机监控系统设计技术规程
DL/T476
Q/GDW383
电力系统实时数据通信应用层协议智能变电站技术导则
Q/GDWZ414变电站智能化改造技术规范
Q/GDW441
Q/GDW534
Q/GDW431
Q/GDW624
Q/GDW678
Q/GDW679
智能变电站继电保护技术规范
变电设备在线监测系统技术导则
智能变电站自动化系统现场调试导则电力系统图形描述规范
智能变电站自动化一体化监控系统功能规范智能变电站一体化监控系统建设技术规范
Q/GDW140-2006交流采样测量装置运行检验管理规程Q/GDW213-2008变电站计算机监控系统工厂验收管理规程
Q/GDWXXX
智能变电站标准化现场调试规范
《国家电网公司电力安全工作规程(变电部分)》国家电网公司
变电站系统设计图纸
设备技术说明书
3.工作流程图
根据调试设备的结构、校验工艺及作业环境,将调试作业的全过程划分为以下校验步骤顺序,见图1。
调试具体流程可根据现场需要进行适度重合,即根据调试人员分工及人员数量,可同时开展两项及以上项目的调试;
项目顺序也可根据现场实际情况进行调整。
1
、
历史库调试
监控主机调试
智能告警与信息综合分析调试
综合应用服务器调试
图1一体化监控系统调试流程图
4.调试前准备
4.1准备工作安排
序号
内容
标准
备注
调试工作前提前2至3天做好摸底工作,结合现场施工情况制定本次工作的调试方案以及安全措施、技术措施
组织措施,并经正常流程审批。
1)摸底工作包括检查现场的调试环境,试验电源供电情况,保护装置及相关
合并单元、智能终端及相关一次设备的安装情况、光纤铺设情况;
2)调试方案应细致合理,符合现场实际能够指导调试工作。
2
根据调试计划,组织作业人员学习作业指导书,使全体作业人员熟悉作业内容、危险源点、安全措施、进度要求、作业标准、安全注意事项。
要求所有工作人员都明确本次校验工作的内容、进度要求、作业标准及安全注意事项。
3
如果是在运行站工作或站内部分带电运行,提前办理工作票,并经运行单
1)工作票应按《电业安全工作规程》相关部分执行;
1)
位许可;
开工前需制定专门的二次安
全措施票。
2)二次安全措施票中所要
求的安全措施应能有效的将工作范围与运行二次回路隔离。
4
准备SCD文件、待调试装置ICD文件保护原理图、二次接线图、光纤联系图、虚端子表、交换机配置表、设备
出厂调试报告、装置技术说明书、装
置厂家调试大纲。
材料应齐全,图纸及资料应符合现场实际情况。
5
检查系统厂内集成测试记录以及出厂验收记录。
系统配置文件SCD正确,系统出厂前经相关部门验收合格。
6
检查调试所需仪器仪表、工器具。
仪器仪表、工器具应试验合格,满足本次作业的要求。
7
开工前与现场安装、施工人员做好交底工作。
了解保护装置及相关合并单元、智能终端等设备的具体情况、现场的可开展试验情况,告知其他工作人员安全风险点及危险区域。
8
试验电源进行检查。
用万用表确认电源电压等级和电源类型无误,应采用带有漏电保护的电源盘并在使用前测试漏电保护装置是否正常。
9
VLAN划分配置检查
1)VLAN应由交换机厂家根据全站虚端子表划分VLAN,没有数据交换的设备不能放在一个VLAN里,并尽量减少跨交换机的数据交换,最终形成excel表格记录。
2)核实现场VLAN划分表格。
3)交换机命名及IP地址4)交换机对时参数;
5)报文记录镜像端口设置;
6)交换机远方通信管理参数(如有)。
7)过程层交换机VLAN配置、GMRP参数配置或静态组播配置。
4.2作业人员要求
现场工作人员应身体健康、精神状态良好,着装符合要求。
工作人员必须具备必要的电气知识,掌握本专业作业技能,熟悉保护设备,掌握保护设备有关技术标准要求,持有保护调试职业资格证书;
工作负责人必须持有本专业相关职业资格证书并经批准上岗。
全体人员必须熟悉《国家电网公司电力安全工作规程》的相关知识,并经考试合格。
新参加电气工作的人员、实习人员和临时参加劳动的人员(管理人员、临时工等),应经过安全知识教育后,并经考试合格方可下现场参加指定的工作,并且不得单独工作。
4.3试验仪器及材料
名称
型号及规格
数量
数字式继电保护测试仪
支持4路以上9-2SV
输出、4路以上goose输入输出,支持对时
功能
1台
标准三相交流信号源
支持电压、电流模拟量的输出
万用表
1只
便携式报文分析仪
SOE高精度测试仪
光源及光功率计
1套
试验直流电源
其它设备
10
11
12
4.4危险点分析及安全措施
防范类型
危险点
预控措施
人身触电
安全隔离
(a)工作前应在危险区域设置明显的警示标识,带电
设备外壳应可靠接地。
接、拆低压电
源
(a)必须使用装有漏电保护器的电源盘。
(b)螺丝刀等工具金属裸露部分除刀口外包绝缘。
(c)接拆电源线时至少有两人执行,必须在电源开关拉开的情况下进行。
机械伤害
落物打击
进入工作现场必须戴安全帽。
防运行
设备误动
如果是在运行
站工作或站内
部分带电运行,误发报文造成装置误动
工作负责人检查、核对试验接线正确,二次隔离措施到位并确认后,下令可以开始工作后,工作班方可开
始工作。
测试中需
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 一体化 监控 系统 标准化 作业 指导书