博科光纤交换机配置命令一览Word格式.docx
- 文档编号:2947717
- 上传时间:2023-05-01
- 格式:DOCX
- 页数:20
- 大小:21.49KB
博科光纤交换机配置命令一览Word格式.docx
《博科光纤交换机配置命令一览Word格式.docx》由会员分享,可在线阅读,更多相关《博科光纤交换机配置命令一览Word格式.docx(20页珍藏版)》请在冰点文库上搜索。
bannersetSetsecuritybanner
bannershowDisplaysecuritybanner
bcastshowDisplaybroadcastroutinginformation
bladebeaconEnablesordisablesbladebeaconingordisplaysthe
currentmode.
bladedisableDisablesalluserportsonablade.
bladeenableEnablesallUserPortsonablade.
burninerrclearClearerrorsthatarestoredinthenon-volatile
storage
burninerrshowDisplayerrorsthatarestoredinthenon-volatile
burninstatusDisplaythediagnosticsburninstatus.
camtestVerifyQuickLoop'
sContentAddressableMemory
(CAM).SIDtranslation
centralmemorytestTestASICcentralmemoryoperation.
cfgactvshowDisplayEffectivezoneconfigurationinformation
cfgaddAddamembertoaconfiguration
cfgclearClearallzoneconfigurations
cfgcreateCreateazoneconfiguration
cfgdeleteDeleteazoneconfiguration
cfgdisableDisableazoneconfiguration
cfgenableEnableazoneconfiguration
cfgremoveRemoveamemberfromaconfiguration
cfgsaveSavezoneconfigurationsinflash
cfgshowPrintzoneconfigurationinformation
cfgsizePrintsizedetailsofzonedatabase
cfgtransabortAbortzoneconfigurationtransaction
cfgtransshowPrintzoneconfigurationsintransactionbuffer
chassisconfigDisplayorsetthechassisconfiguration
chassisnameDisplayorsetthechassis'
sName
chassisshowDisplayallFieldReplaceableUnits(FRU)
chipregshowDisplaystheportregistersforagivenchip
number.
cmemretentiontestDataretentiontestofthecentralmemorySRAMs.
cmitestVerifyCMIbusbetweenASICs.
configdefaultResetconfigtofactorydefault
configdownloadLoadswitchconfigfromaserver
configshowPrintswitchconfigparameters
configuploadSaveswitchconfigtoaserver
configureSetswitchconfigparameters
datatypeshowDisplayavailablediagnosticdatatypes.
datePrint/setthesystemdateandtime
dbgshowDisplaydebuglevelsofvariousmodules
defzoneActivatesordeactivatesadefaultzone
diagclearerrorClearsdiagnosticsfailurestatus.
diagcommandshowDisplaydiagnosticcommanddescriptions.
diagdisablepostDisablediagnosticPOST.
diagenablepostEnablediagnosticPOST.
diagenvDiagnosticdebugparametersmanagementpackage.
diaghelpDisplaydiagnosticcommanddescriptions.
diagloopidSelectthediagnosticsloopID.
diagmodeshowDisplaysdiagnosticmodeconfiguration.
diagpostDisplaysthecontentsofportregistersand
memories.
diagretrySetsdiagnosticretrymode
diagsetburninInitializesthebladeforaburninrun.
diagsetcycleSetdiagnosticscriptparameters.
diagsetesdmodeSetordisplayESDmode.
diagsetshowtimeSetordisplaydiagnosticshow-timemode.
diagshowDisplaydiagnosticstatus.
diagshowtimeSetordisplaydiagnosticshow-timemode.
diagstatusDisplaycurrentlyrunningdiagnostictests.
diagstopburninTerminateburninrunonablade.
distributeDistributesdatatoswitchesinafabric.
dlsresetTurnoffthedynamicloadsharing(DLS)option
dlssetTurnonthedynamicloadsharing(DLS)option
dlsshowDisplaythestateofthedynamicloadsharing
option
dnsconfigConfigureDNSservice
enclosureshowDisplaytheswitchenclosureattributes
errclearClearerrorlog
errdelimitersetSetstheerrorlogstartandenddelimiterfor
messagessenttotheconsoleandsyslog
errdumpPrinterrorlog(nopagebreaks)
errfiltersetSetsafilterforanerrorlogdestination
errmoduleshowDisplaysallthedefinedmodulesinthesystem
errshowPrinterrorlog
fabportshowDisplaycontentsofaparticularport'
sdata
fabretryshowDisplayretrycountofvariousfabriccommands
fabriclogDisplaysormanipulatesthefabriclog
fabricprincipalDisplays/Enables/DisablesPrincipalSwitch
Selectionmode
fabricshowPrintfabricmembershipinfo
fabstateclearClearsthefabricstateinformation
fabstateresizeChangesthenumberofstateentries
fabstateshowDisplaysthefabricstateinformation
fabstatsshowDisplaysthefabricstatisticsinformation
fabswitchshowDisplayfabricswitchstateinformation
fandisableDisablesafanunit.
fanenableEnablesafanunit.
fanshowPrintfanstatus
fastbootRebootthisswitchandbypassPOST
fastwritecfgConfigureFCfastwritefeature
fazoneaddAddamembertoafabricassistzone
fazonecreateCreateafabricassistzone
fazonedeleteDeleteafabricassistzone
fazoneremoveRemoveamemberfromafabricassistzone
fazoneshowPrintFabricAssistZoneinformation
fcipchiptestFunctionalTestofComponentsinFCIPComplex.
fciphelpPrintFCIPhelpinfo
fcippathtestDataPathTestoftheFCIPcomplex.
fcpingSendsaFCELSECHOrequesttoaport
fcplogclearCleartheFCPlog
fcplogdisableDisableloggingofFCPevents
fcplogenableEnableloggingofFCPevents
fcplogshowDisplayFCPprobingloginformation
fcpprobeshowDisplayFCPprobinginformation
fcprlsshowDisplayFCPRLS(readlinkstate)information
fcrchiptestFunctionalTestofFCRFPGA.
fcrconfigureSetsFCRouterconfigurationparameters.
fcrfabricshowDisplaysFCRoutersonabackbonefabric.
fcrlsancountDisplaymaximumLSANzonelimit.
fcrlsanmatrixManageLSANfabricmatrixconfiguration.
fcrpathtestDataPathTestonConnectionbetweenFCRFPGAand
CentralASIC.
fcrphydevshowDisplaysFCRouterphysicaldeviceinformation.
fcrproxyconfigDisplaysorconfiguresproxydevicespresentedby
anFCRouter.
fcrproxydevshowDisplaysFCRouterproxydeviceinformation.
fcrresourceshowDisplaysFCRouterphysicalresourceusage.
fcrrouterportcostDisplaysFCRouterrouteinformation.
fcrrouteshowDisplaysFCRouterrouteinformation.
fcrxlateconfigDisplaysorpersistentlyconfiguresatranslate
(xlate)domain'
sdomainIDforboth
EX_Port-attachedfabricandbackbonefabric.
fddcfgfddcfgmanagesthefabricdatadistribution
configurationparameters.
fdmicacheshowDisplayabbreviatedremoteFDMIdeviceinformation
accordingtoremotedomainID
fdmishowDisplaydetailedFDMIdeviceinformation
ficonclearClearscontentsofthespecifiedFICONmanagement
database
ficoncupsetSetsFICON-CUPparametersforaswitch
ficoncupshowDisplaysFICON-CUPparametersforaswitch
ficonhelpDisplaysFICONcommands
ficonshowDisplayscontentsofthespecifiedFICONmanagement
filtertestRunframefiltertestforbloomASICs.
firmwarecommitCommitfirmwaretostablestorage
firmwaredownloadDownloadfirmwareintoswitch
firmwaredownloadstatusDisplaytheprogressandstatusoffirmwareDownload
firmwarerestoreRestoretheoldfirmwareintheswitch
firmwareshowDisplayfirmwareversionsintheswitch
fosconfigEnable/disableFabOSservices
fporttestFunctionaltestofF->
NN->
Fpointtopointpath.
framerpathtestTestsdatapathbetweenASICs
frureplaceReplaceaFieldReplacableUnit
fspfshowPrintFSPFglobalinformation
fwalarmsfiltersetConfigurealarmsfilteringforFabricWatch
fwalarmsfiltershowShowalarmsfilteringforFabricWatch
fwclassinitInitializeallFabricWatchclasses
fwconfigreloadReloadFabricWatchconfiguration
fwconfigureConfigureFabricWatch
fwfrucfgConfigureFRUstateandnotification
fwhelpPrintFabricWatchhelpinfo
fwmailcfgConfigureFabricWatchEmailAlert
fwportdetailshowCreateareportwithdetailedportinformation
fwsamshowShowavailabilitymonitorinformation
fwsetSetportpersistencetime
fwsettocustomSetboundary&
alarmleveltocustom
fwsettodefaultSetboundary&
alarmleveltodefault
fwshowShowthresholdsmonitoredandportpersistencetime
grepLinuxgrepcommand
hPrintshellhistory
hadisableDisablestheHighAvailabilityfeatureinthe
switch.
hadumpDisplaysinformationaboutthestatusoftheHigh
Availabilityfeatureintheswitch.
haenableEnablestheHighAvailabilityfeatureintheswitch
hafailoverForcesthefailovermechanismsothattheStandby
ControlProcessor(CP)becomestheActiveCP.
hashowDisplayscontrolprocessor(CP)status
hasyncstartEnablesHAstatesynchronization.
hasyncstopDisablestheHAstatesynchronization.
helpPrintthislist
historylastshowDisplayslasthistoryrecord
historymodeDisplayorsetthemodeofthehistorylog
historyshowDisplaysentirehistorylog
httpcfgshowUsedtoshowtheversionoftheJavaplug-inused
bytheWebtools
iDisplayprocesssummary
ifmodesetSetthelinkoperatingmodeforanetworkinterface
ifmodeshowDisplaythelinkoperatingmodeforanetwork
interface
interfaceshowDisplaytheFSPF(TM)interfaceinformation
interopmodeDisplays/enables/disablesBrocadeswitch
interoperabilitywithswitchesfromother
manufacturers
iodresetTurnoffthein-orderdelivery(IOD)option
iodsetTurnonthein-orderdelivery(IOD)option
iodshowDisplaythestateofthein-orderdeliveryoption
ipaddrsetSetethernetandFCIPaddresses
ipaddrshowPrintethernetandFCIPaddresses
ipfilterManage/displayIPfilters
iscsihelpPrintiSCSIhelpinfo
islshowDisplaythecurrentconnectionsandstatus
killtelnetTerminatetelnet/serialloginsessions
interactively
licenseaddAdds
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 光纤 交换机 配置 命令 一览