d,h:
m:
s?
Logout
--------------?
---------
off?
9,21:
34:
43?
20?
min
PS1-Type?
PS2-Type
--------------------?
--------------------
WS-CAC-1300W?
Modem?
Baud?
Traffic?
Peak?
Peak-Time
-------?
-----?
----?
-------------------------
disable?
9600?
0%?
5%?
Fri?
Jul?
23?
2004,?
17:
39:
44
PS?
Configuration?
:
PS1?
and?
PS2?
in?
Redundant?
Configuration.
System?
Name?
Location?
Contact?
CC
------------------------?
--
Catalyst6509
做红色标注的为检测时对于系统输出的关注点。
Environmental?
Status?
(.?
=?
Pass,?
F?
Fail,?
U?
Unknown,?
N?
Not?
Present)
PS1:
.?
PS2:
Fan:
.
Chassis-Ser-EEPROM:
Clock(A/B):
A?
Clock?
A:
B:
VTT1:
VTT2:
VTT3:
environmen?
Slot?
power?
Requirement/Usage?
Card?
Type?
PowerRequested?
PowerAllocated?
CardStatus
Watts?
@42V?
@42V
-------------------?
------?
----------
1?
WS-X6K-SUP1A
2?
WS-X6408A
风扇状态检测
Catalyst6500,C4500,C4000系列交换机,?
在enable模式下可以用以下命令检测设备的风扇状态:
注:
温度状态检测
Catalyst6500,C4500,C4000系列交换机,在enable模式下可以用以下命令检测检测系统温度状态:
temperature
temperature?
Intake?
Exhaust?
Device?
2
Temperature?
Temperature
---------------?
---------------
20C(50C,65C)?
28C(60C,75C)?
24C?
31C?
18C(50C,65C)?
23C(60C,75C)?
N/A?
3?
21C(50C,65C)?
19C(60C,75C)?
4?
22C(50C,65C)?
25C(60C,75C)?
21C?
22C?
(Switch-Eng)?
25C(50C,65C)?
29C(60C,75C)?
(MSFC)?
23C(60C,70C)?
32C(60C,75C)?
Chassis?
Modules
---------------------
20C(85C,100C)?
23C(85C,100C)?
二 Cisco?
IOS?
C4500?
IOS系列交换机
IOS,C4006?
sup3?
IOS系列交换机,?
C6509#?
redundancy?
mode?
redundant
Power-Capacity?
PS-Fan?
Output?
Oper
State
------------------?
-----
none
Pwr-Requested?
Pwr-Allocated?
Admin?
Card-Type?
State?
Router#
Switch4507#?
Power?
Fan?
Inline
Supply?
Model?
No?
Sensor?
Status
----------------?
---------?
-----------?
------
PWR-C45-2800AC?
AC?
2800W?
good?
PWR-C45-1000AC
***?
Supplies?
of?
different?
type?
have?
been?
detected***
supplies?
needed?
by?
1
currently?
available?
Summary?
Maximum
(in?
Watts)?
Used?
Available
----------------------?
(12V)?
328?
1360
Inline?
(-50V)?
0?
1400
----
Total?
338?
(not?
to?
exceed?
Maximum?
Available?
750)
Switch#
IOS,C4500系列交换机,?
cooling
environment status
fan-tray?
1:
fan-fail:
failed
2:
fan?
type:
FAN-MOD-9
OK
chassis?
cooling?
capacity:
690?
cfm
ambient?
temperature:
55C?
["
40C?
(user-specified)"
if?
temp-controlled]
per?
slot?
75?
module?
requirement:
70?
5?
30?
6?
8?
9?
Catalyst6500IOS,C4500IOS系列交换机,在enable模式下可以用以下命令检测检测系统温度状态:
SwitchC4507#?
no?
alarm?
35?
degrees?
Celsius
Over?
Threshold?
Critical?
95?
types?
Switch
三 Cisco?
Catalyst3550,C2950,C3500,C2900系列交换机
Catalyst3550,C2950,C3500,C2900系列交换机,?
env?
Catalyst3550#show?
POWER?
is?
对于Cisco?
Fan
Catalyst3550#?
FAN?
在enable模式下可以用以下命令检测系统温度状态:
TEMPERATURE?
四 Cisco?
2600,3600,7200,7500,7600系列路由器
对于Cisco 2600,3600,7200,7500,7600系列路由器,?
Router#?
对于Cisco 2600,3600,?
7200,7500,7600系列路由器,?
在enable模式下可以用以下命令系统风扇状态:
在enable模式下可以用以下命令系统温度状态:
status
status?
backplane:
operating?
clock?
count:
VTT?
3
WS-9SLOT-FAN
OK:
outlet?
33C
35C
3:
OK,?
clock-inuse:
in-use
not-in-use
power-supply?
power-output-fail:
30C
device-2?
RP?
inlet?
36C
EARL?
31C
29C
4:
32C
5:
39C
34C
7:
7?
42C
45C
9:
41C
N/O
此命令为监控系统环境的综合命令,后面可以加上多种参数,以便于综合分析系统状态。
[alarm?
|?
temperature]
environmental?
alarms:
alarms
五 Cisco?
GSR?
12000系列路由器
12000系列路由器,?
Diag
router#?
diags
SLOT?
26?
(PS?
B1?
Supply(8)
HW?
config:
0xFF?
SW?
key:
FF-FF-FF
MBUS:
MBUS?
Agent?
(1)?
73-2146-07?
rev?
B0?
dev?
Test?
hist:
RMA#:
FF-FF-FF?
RMA?
0xFF
DIAG:
0xFFFFFFFF?
results:
0xFFFFFFFF
EEPROM?
contents?
(hex):
00:
01?
00?
- 配套讲稿: