湿热灭菌的验证方案
湿热灭菌程序的验证:
灭菌程序的设计、开发、确认以及日常控制
1.0引言.............................................................................................................................................4
1.1范围......................................................................................................................................4
2.0术语.............................................................................................................................................5
3.0灭菌科学...................................................................................................................................11
3.1灭菌模式...........................................................................................................................12
3.1.1耐热参数(DT).....................................................................................................13
3.1.2温度系数(z值)...................................................................................................15
3.1.3灭菌率(LethalRate)和累计杀灭时间(lethality,F)....................................16
3.2灭菌指示剂........................................................................................................................20
3.2.1生物指示剂(BIs)................................................................................................20
3.2.2化学监测器.............................................................................................................21
3.3热力学和蒸汽质量............................................................................................................22
3.3.1温度和热量.............................................................................................................22
3.3.2蒸汽.........................................................................................................................28
3.3.3纯蒸汽质量的测试.................................................................................................28
4.0灭菌程序的开发......................................................................................................................30
4.1设计方法...........................................................................................................................30
4.1.1灭菌程序设计方法中残存曲线的应用.................................................................31
4.2装载类型...........................................................................................................................34
4.2.1多孔/坚硬装载的定义............................................................................................34
4.2.2液体装载的定义.....................................................................................................34
4.3灭菌程序...........................................................................................................................35
4.3.1饱和蒸汽灭菌程序.................................................................................................35
4.3.2空气加压程序.........................................................................................................38
4.4灭菌程序的开发...............................................................................................................40
4.4.1多孔/坚硬装载灭菌程序的开发............................................................................40
4.4.2液体装载灭菌程序的建立.....................................................................................45
4.5稳定性研究.......................................................................................................................48
5.0灭菌程序的性能确认..............................................................................................................48
5.1物理确认...........................................................................................................................49
5.1.1热分布.....................................................................................................................49
5.1.2热穿透.....................................................................................................................49
5.2生物指示剂确认...............................................................................................................50
5.2.1生物指示剂挑战系统.............................................................................................50
5.2.2生物指示剂的使用和放置.....................................................................................51
5.3灭菌程序性能确认合格标准...........................................................................................52
5.4等效灭菌器........................................................................................................................53
5.5分组法...............................................................................................................................54
5.5.1典型产品法.............................................................................................................54
5.5.2典型容器规格/装量法............................................................................................54
5.5.3典型物品法.............................................................................................................54
5.5.4典型装载法.............................................................................................................54
6.0日常工艺控制..........................................................................................................................55
6.1常规放行...........................................................................................................................55
6.2灭菌器系统的适用性试验...............................................................................................55
6.3变更控制...........................................................................................................................55
6.4灭菌程序定期再确认.......................................................................................................56
7.0参考文献..................................................................................................................................56
1.0引言
PDA的原始技术报告第一期“蒸汽灭菌程序的验证”于1978年出版,它为一代制药科学
家和工程师介绍了蒸汽灭菌的原理。
原文的重点是湿热灭菌的微生物学和工程设计,本修订
版仍以此为中心,并通过更新以包括近代出现的课题。
本报告参考了最新的科技出版物、国
际法规文件、期刊文章、技术论文和书籍,从中可查得更多详细并有说服力的数据和资料。
特别工作小组的主要目的是编写一个湿热灭菌的科学技术报告,它可在所有监管的法规
环境中加以应用。
报告并不立足于阐述区域性法规的要求,而是向工业和监管部门提供最新
的科学建议。
应将本报告看作一个指南。
本文无意确立湿热灭菌验证的标准,它只是对现有
参考文献作系统的回顾和总结。
特别工作组由欧洲和北美工业界和监管方面的专家组成,以保证所述方法、术语和做法
具有良好的科学性,以致可以在全球范围内加以应用。
本技术报告曾以草案的形式,在公开
征求意见后出版,以保证其作为一个有价值的资料,能够指导工业界的蒸汽灭菌。
本技术报告总体目标是提供理解湿热灭菌科学所需的必要信息及技术细节,为制订灭菌
方针提供方便。
1.1范围
新的标题“湿热灭菌的验证--灭菌程序的设计、开发、确认和日常监控”反映了本技术
报告的重点放在生产上。
报告按逻辑次序编排,从灭菌科学的原理/要素开始,然后是灭菌程序的开发和灭菌程
序的确认,见图1.1-1。
图1.1-1灭菌科学的应用
为便于理解报告的内容,本文开头就列出了技术性术语(包括同义词)。
围绕“验证”这
一总的主题,按图1.1-1的程序讨论了包括热力学(第3.0节)在内的微生物学、灭菌科学
和灭菌程序,因为它们本指南图1.1-1所述内容的基础。
工艺开发(第4.0节)--介绍了药品生产中实际应用的灭菌程序(过度杀灭和按具体产
品特点来确定程序)的设计理论。
可用决策树来指导怎样选择各类产品最恰当的灭菌程序。
为了方便评估灭菌工艺不同阶段的风险,列出了液体和多孔/坚硬1
装载灭菌工艺参数示例
表。
本节指导产品或物品的湿热灭菌法的使用者,如何将灭菌科科学的理论应用于实际。
灭菌工艺的性能确认(第5.0节)--是灭菌程序验证的核心。
采用物理和生物指示剂(下
文中有时会采用BI表述)二种方法来阐述一个生产企业或其他设施灭菌程序的性能确认。
它在讨论中包括了必要的实践和科学理论,以证明灭菌系统达到了所要求的杀灭效果
(lethality)。
日常监控(第6.0节)--阐述日常性能监控的要求,以保持灭菌程序的受控状态。
本节
还包括变更控制、系统适用性及定期再确认的内容。
并不要求将本技术报告中所述概念,应用于包括医院在内的实验室或者其他无cGMP
要求的单位。
本技术报告中没有包括其他一些重要因素,如设施、设备、维护保养、公用工
程和分析方法的确认。
2.0术语
每个公司对术语的使用不尽相同,有一些术语将来可能会发生变化。
然而,在一个公司
内,验证方案中所采用的术语必须清晰、明确,易于理解。
监管部门的指南可能会采用另一
些定义,应考虑这种情况。
本技术报告采用以下术语并同时附上相应的定义及必要的同义词。
空气检测器AirDetector
安装于饱和蒸汽灭菌器上用以检测灭菌器腔室中空气的装置。
空气增压灭菌程序AirOverpressureSterilizationProcess
指在大于饱和蒸汽压的控制压力下运行的湿热灭菌程序,通常用压缩空气使灭菌腔室达到所
需的压力
空气去除试验AirRemovalTest
用于评估灭菌器空载条件下空气去除和蒸汽穿透的一种试验(例如,Bowie-Dick测试法,
DART,LantorCube,Browns测试法),此类灭菌器用于多孔/坚硬物品类装载的灭菌。
生物指示剂挑战系统BiologicalIndicatorChallengeSystem
一个含有纯的特定的菌株的活的微生物测试系统,此系统对某一灭菌程序具有规定的耐受
性。
(1)[同义词:
BIChallengeSystem-生物指示剂挑战系统,MicrobialChallenge-微生物挑
战,MicrobiologicalChallengeSystem-微生物挑战系统]
生物指示剂确认BiologicalQualification
采用生物指示剂来证明整个装载(被灭菌品)始终能达到所规定生物杀灭时间(FBIO值)的
试验。
它是性能确认的组成部分。
分组法BracketingApproach
将待试验的产品和(或)装载按其特性(如粘度、容器规格、装量、物品大小、装载方式)
在上和(或)下限进行确认及验证的科学方法
仪器的校准Calibration
采用与相关标准或者源于国内或国际的标准进行比较,以证明一项仪器或设备所得结果符合
规定限度标准的活动。
灭菌器腔室Chamber
灭菌器用以放置被灭菌物品的主要组成部分。
灭菌器腔室是一个有额定压力的容器。
灭菌器腔室的冷点ChamberColdSpot
在灭菌程序中,装载区域中被灭菌品F0值最低和/或热分布试验中温度最低的位置。
灭菌器腔室的升温时间ChamberHeat-UpTime
从蒸汽进入灭菌器腔室开始至加热介质达到设定灭菌温度的时间。
腔室检漏试验ChamberLeakTest
为评估真空条件下灭菌器腔室中是否有空气渗入而进行的试验。
[同义词:
VacuumLeakTest
真空检漏试验]。
化学指示剂ChemicalIndicator
系指根据受热导致物理或化学变化的原理,显示一个或多个预定变量的试验系统
(2)2
。
多变量化学指示剂ChemicalIntegrator
能定量地反映灭菌程序中多个变量(尤其是时间、温度和某些情况下的湿度)累计变化的系
统
冷却阶段Cool-DownPhase
指灭菌程序中灭菌完成之后的阶段。
通常须定义冷却阶段的参数,以符合有些用户对被灭菌
品冷却和干燥的技术要求。
容器的冷点ContainerColdSpot
指灭菌程序中,密封液体容器中F0最低的位置。
蒸汽干度DrynessFraction4
一个蒸汽样品中,实际潜热与饱和蒸汽理论潜热之比。
干度值DrynessValue
近似蒸汽干度且无单位的测试值。
DT值DT-Value耐热参数5
在规定的灭菌条件下,使所用生物指示剂的数量下降一个对数单位,或杀灭90%所需的时
间。
在湿热灭菌中,D值总需注明参照温度,即以DT表示。
例如,一个D121℃=1.4分钟的
生物指示剂系统,表示在121℃下,杀灭90%的芽孢需要1.4分钟。
平衡时间EquilibrationTime
指灭菌器的参照测试点(通常是排水口)达到最低灭菌温度开始,到装载中所有点均达到灭
菌温度之间的时间间隔。
它体现了灭菌器去除装载中空气并对其加热的能力。
通常要求将热
穿透探头放置在多孔/坚硬装载中才能对此进行评估。
灭菌保温阶段ExposurePhase
系指灭菌程序中,为获得设定杀灭效果,保持设定灭菌温度的持续时间(保温时间或保温阶
段)。
F值F-Value(lethalityFactor)累计杀灭时间
系灭菌效力的度量值。
F(T,Z)是在规定的Z值下,一个灭菌程序赋予一被灭菌物品在参照温度
T℃下的等效灭菌时间,简称T℃灭菌时间。
Fphy系指以灭菌程序的物理参数计算的物理杀灭时间。
Fphysical--是灭菌率L对时间的积
分值。
L(灭菌率)用公式:
L=10(T-Trefe)/Z
计算。
注意:
参照温度121.1℃在数学上近似250°F,为简化计算,本文此后将采用121℃。
F0值(标准灭菌时间),是指Z取10℃时,一个湿热灭菌程序赋予被灭菌品121.1℃下灭
菌的等效灭菌时间。
例如,当生物指示剂的z取10℃,F(T=121.1℃,z=10℃)赋予产
品8分钟的程序,或F0为8,与一个116℃灭菌25.9分钟方形灭菌波是等效的,F0均为8。
FBIO系指灭菌程序的生物杀灭时间。
它是生物指示剂挑战试验系统中微生物实际杀灭效
果的量度。
生物杀灭时间可以DT×LR计算获得,这里,DT是生物指示剂系统以T度为参
照温度下的D值,LR是灭菌过程中生物指示剂实际的对数单位下降值(logLgN0-LgNF)。
阴性分数法Fraction-NegativeMethods
阴性分数法是指根据生物指示剂的初始菌数(N0)以及有效暴热时间建立二点存活曲线获得
的数据并依此确定DT值的方法。
有效暴热时间是指试样灭菌的时间范围,在此范围内被灭
菌的一组试样,应得到两个相反的结果,即一些样品为阳性,另一些样品则为阴性。
重力置换程序Gravity