May2017FUJITSULIMITED,DX100S4/DX200S4DX100S3/DX200S3DX500S3/DX600S3DX200F/AF250/AF650Maintenance,FUJITSUCONFIDENTIAL,Copyright2017FUJITSULIMITED,RefertothefollowingdocumentswheninstallingandexpandingETERNUSDX/AFSeries.MaintenanceManual(forS3/AF):
R11B-1393-01ENMaintenanceManual(forS4):
R11B-1707-01ENThisnumberistheversionthatisupdatedeveryrevision.AlltheabovedocumentscanbedownloadedfromGSDWeb.(Needtoregisteryouraccountandpassword.)http:
/localhost/cache/7124143024003106/png/global,FUJITSUCONFIDENTIAL,1,Copyright2017FUJITSULIMITED,MaintenanceManual,WEBGUIMenu-Overview-,DisplayswhenloggingontoWebGUI,andindicatesthestatusofUNIT.,FUJITSUCONFIDENTIAL,2,Copyright2017FUJITSULIMITED,Overview,OverviewscreenappearswhenloggingontoUNITWhetherUnifiedOptionisenabledornotisconfirmablein“UnifiedStorage”item.,FUJITSUCONFIDENTIAL,3,Copyright2017FUJITSULIMITED,WEBGUIMenu-Components-,Displaysinformationandstatusofinstalledcomponents,andperformsvarioussettingsandcontrols.,FUJITSUCONFIDENTIAL,4,Copyright2017FUJITSULIMITED,Components,TopscreenThisscreenshowsinformationandthestatusofUNIT.,FUJITSUCONFIDENTIAL,5,Copyright2017FUJITSULIMITED,SelectanactionSelectacomponenttoexecutemaintenanceworksuchasPreventiveMaintenance,ForcedDegradation,Forcedbuilt-inandHotReduction,andvarioussettings.,Components,FUJITSUCONFIDENTIAL,6,Copyright2017FUJITSULIMITED,HotPreventiveMaintenanceThisfunctionistoreplaceacomponentwhileUNITisoperating.Targetcomponents:
CM/DIMM/BUD/CMFAN/CA/CASFP/PFM/CPSU/BCU/BTU/IOM/FEM/PSU/SASCable/HDD/SSD,Components,FUJITSUCONFIDENTIAL,7,Copyright2017FUJITSULIMITED,ForceDisableThisfunctionisusedtoforciblydegradecomponents.TargetParts:
CM/CA/CASFP/CPSU/PFM/BCU/BTU/IOM/FEM/PSU/SASCable/HDD/SSD,Components,FUJITSUCONFIDENTIAL,8,Copyright2017FUJITSULIMITED,ForceEnableThisfunctionisusedtoforciblyreinstallinthesamecomponentremovedfromthesystemduetoafailurewithoutreplacingwithanewone.TargetParts:
CM/CA/CASFP/PFM/IOM/FEM/HDD/SDD,FUJITSUCONFIDENTIAL,9,Copyright2017FUJITSULIMITED,Components,HotDEExpansionThisfunctionisusedtoexpandDEwithoutstoppingthesystem.,FUJITSUCONFIDENTIAL,10,Copyright2017FUJITSULIMITED,Components,ChannelAdapter-HotExpansionofCAThisfunctionisusedtoaddCAwithoutstoppingthesystem.,Components,FUJITSUCONFIDENTIAL,11,Copyright2017FUJITSULIMITED,ControllerModuleHotExpansionofmemoriesThisfunctionisusedtoaddmemorieswithoutstoppingthesystem.,Components,FUJITSUCONFIDENTIAL,12,Copyright2017FUJITSULIMITED,DriveEnclosureHotReductionofDriveEnclosureThisfunctionisusedtoreduceDEwithoutstoppingthesystem.,Components,FUJITSUCONFIDENTIAL,13,Copyright2017FUJITSULIMITED,ChannelAdapterHotReductionofChannelAdapterThisfunctionisusedtoreduceCAwithoutstoppingthesystem.,FUJITSUCONFIDENTIAL,14,Copyright2017FUJITSULIMITED,Components,DrivesHotReductionofDriveThisfunctionisusedtoreducedriveswithoutstoppingthesystem.,Components,FUJITSUCONFIDENTIAL,15,Copyright2017FUJITSULIMITED,IDENTIFYLEDThisfunctionenablestocontroltheblinkandon/offofIDLEDonCEpanelandCMUNIT.,Components,FUJITSUCONFIDENTIAL,16,Copyright2017FUJITSULIMITED,Drives-ErrorStatisticsThisfunctionenablestobrowseoccurrenceoferrorsindrives.,Components,FUJITSUCONFIDENTIAL,17,Copyright2017FUJITSULIMITED,DriveEnclosure-I/OModule-ErrorStatisticsPorterrorinformationThisfunctionenablestobrowseoccurrenceoferrorstheSASpath.,Components,FUJITSUCONFIDENTIAL,18,Copyright2017FUJITSULIMITED,DrivesStartDiagnosisDiskdiagnosis(Detectsdiskerrors.),FUJITSUCONFIDENTIAL,19,Copyright2017FUJITSULIMITED,Components,DrivesSSDdataerasingThisfunctionistoeraseSSDdata.,Components,20,Copyright2017FUJITSULIMITED,ControllerEnclosureControllerModuleNASSystemVolumeRecoveryRecoversystemvolumesofNASEngine(rootfilesystem)toforciblyrecoverNASEngine.,Component,FUJITSUCONFIDENTIAL,21,Copyright2017FUJITSULIMITED,ControllerEnclosureControllerModuleNASEngineRecoveryRecovertheadministrativeregionofNASEngineandremoveinconsistencyfromtheadministrativedatatorecoverNASEngine.,Component,FUJITSUCONFIDENTIAL,22,Copyright2017FUJITSULIMITED,WEBGUIMenu-RAIDGroup-,ShowsinformationandstatusofRAIDgroupsinUNIT,andalsoconfiguressettingsandcontrols.,FUJITSUCONFIDENTIAL,23,Copyright2017FUJITSULIMITED,RAIDGroup,TopwindowReferstoalistandinformationofRAIDgroups.,FUJITSUCONFIDENTIAL,24,Copyright2017FUJITSULIMITED,RAIDGroupStartDiagnosisThisfunctionenablestoconfirmRAIDconsistencyandverifydata.,RAIDGroup,FUJITSUCONFIDENTIAL,25,Copyright2017FUJITSULIMITED,RAIDgroup-RecoverRAIDGroupThisfunctionenablestorecoverRAIDgroupswithForcedRecover(abletorecoverdata)or“RecoverwithDiskMaintenance(unabletorecoverdata)“.,RAIDGroup,FUJITSUCONFIDENTIAL,26,Copyright2017FUJITSULIMITED,WhatisaRAIDfailure?
TheredundancyislostinRAIDgroups,andadiskerrorisoccurred.Datacannotbeaccessednormally.,WhatisaRAIDfailure?
HS,ExampleofRAIDfailure(RAID5(3+1),Failure,HS,FailureFailure,Sourcediskofrebuildingfailed,Non-redundantARAIDfailureoccurred!
DataaccesswhenRAIDfails?
DataaccesstovolumesoftheRAIDgroupwhoseRAIDfails:
Writingdata-inapplicableReadingdata-Allowstoreadsothatdataissavedasmuchaspossible.,Broken,Broken,FailedUsable,Berebuilding,FUJITSUCONFIDENTIAL,27,Copyright2017FUJITSULIMITED,DisplayofDiskStatusDisksdisconnectedwhenRAIDGroupsareredundantTransitiontotheBrokenstateDisksdisconnectedwhenRAIDGroupsarenotredundantTransitiontotheFailedUsablestate*InordertopermitDataReadwhenRAIDfails,thesystemcontinuestooperatetherelevantDisksbythetransitiontotheFailedUsablestateDisplayofRAIDGroupStatusTheRAIDGrouptransitionstotheBrokenstateExternalindicationBrokenDiskFaultLED(amber)litFailedUsableDiskFaultLED(amber)unlitMAINTENANCELEDblinksgreen,FUJITSUCONFIDENTIAL,28,Copyright2017FUJITSULIMITED,DisplaywhenRAIDfails,RecoveryfromaRAIDfailureUseRecoverRAIDGrouponWebGUI/CLItorecoverRAIDgroupfromRAIDfailurestate.Therearetwotypesofrecoveries;ForcedRecoverRAIDGroupandDriveMaintenance.DriveMaintenance(Unabletosavedata)ReplacingallthedisksinthestateofFailedUsableandBroken,discardsdataondiskstorecoverfromRAIDfailure.*AllthedataintheRAIDgrouparelost.ForcedRecoveryRAIDGroup(Abletosavedata)ThisfunctionrecoversRAIDGroupsfromthefailureswithoutreplacingFailedUsablediskswithdataretainedondisks(Aftertherecovery,theBrokendisksshouldbereplacedseparately)*Thedatasavingisnotguaranteed100%.ThedatacannotbesaveddependingoncausesofFailedUsablediskfailures.,FUJITSUCONFIDENTIAL,29,Copyright2017FUJITSULIMITED,RecoveryfromaRAIDfailure,WhendatahasnotbeenbackedupBackupdata(dataRead)inRAIDbrokenstateasmuchaspossible.Ifbackupfails,gotostep2.RecoverfromRAIFfailureswith“ForcedRecoverRAIDGroup”.Ifsucceeded,re-backupallthedata.IfbackuphasfailedorrecoveryfromRAIDfailurewasfailed,gotostep3.2.Datacannotbesaved.IfRAIDfails,recover“DriveMaintenance”toformatallthevolumesintherelevantRAIDGroup.IfRAIDdoesntfail,replaceallthe“Broken”Diskswithmaintenanceparts.4.WhenUnifiedoptionisenabled,refertoMAP0031000“UnifiedStorage:
MaintenanceProcedures”torecoverfromRAIDfailure.,FUJITSUCONFIDENTIAL,30,Copyright2017FUJITSULIMITED,GuidelineofrecoveryprocedurefromRAIDfailure,Whenbackupdataexistsordatabackuphasbeensucceeded:
IfRAIDfails,recover“DriveMaintenance”toformatallthevolumesintherelevantRAIDGroup.IfRAIDdoesntfail,replaceallthe“Broken”DisksandDisksintheFailedUsablestatewithmaintenanceparts.WhenUnifiedoptionisenabled,refertoMAP0031000UnifiedStorage:
MaintenanceProcedurestorecoverfromRAIDfailure.Restoredatafrombackupdestination.,FUJITSUCONFIDENTIAL,31,Copyright2017FUJITSULIMITED,GuidelineofrecoveryprocedurefromRAIDfailure,WEBGUIMenu-Volume-,ShowsinformationandthestatusofeachvolumeinUNIT,andconfiguressettingsandcontrols.,FUJITSUCONFIDENTIAL,32,Copyright2017FUJITSULIMITED,Volume,TopScreenThisfunctionenablestorefertothestatusofvolumes.,FUJITSUCONFIDENTIAL,33,Copyright2017FUJITSULIMITED,Volume,Volume-PinnedDataThisfunctionenablestowritebackanddeletePinneddataoccurredinUNIT.*WhendeletingPinneddatainvolumesforNAS,recoveryisrequiredinreferencetoMaintenanceProcedureforNAS.,FUJITSUCONFIDENTIAL,34,Copyright2017FUJITSULIMITED,WhatarePinnedData?
Writedatathatcannotbewrittenfrom/view13/M02/2E/35/wKh2DmFud8WAUUYsACopyright2017FUJITSULIMITED,FUJITSUCONFIDENTIAL,VisualizationofPinnedData,FUJITSUCONFIDENTIAL,36,Copyright2017FUJITSULIMITED,VisualizationofPinnedDataWhenPinnedDataoccursinUNIT,theoccurrenceanddisappearancecanbecheckedEnablestocheckBADDataoccurrencesfromGUI/CLIExternalindicationCEPanelFaultLEDBlinkingamber(Warningstatus)GUIindicationSystemStatusPinnedDataSystemMessageDisplaysthemessageindicatingtheoccurrenceofPinnedDataPinnedDatascreenDisplaysoccurrencelocationofPinnedDataEventnotificationWhenPinnedDataoccurred“PINNEDDATAwascreatedCM#m”WhenPinnedDatadisappeared“PINNEDDATAwasclearedCM#m”,Volume,Volume-BadSectorThisfunctionenablestodeletebadsectors(baddata)generatedinUNIT.*WhendeletingPinneddatainvolumesforNAS,recoveryisrequiredinreferencetoMaintenanceProcedureforNAS.,FUJITSUCONFIDENTIAL,37,Copyright2017FUJITSULIMITED,BADDataThesizeofeachBADdatais512Bytes.Baddataiscl